gas fires fireplaces
 

A UK gas fire fireplaces Company

Focal Point Fires KENSINGTON Power Flue
Requires no existing chimney or flue. Vents directly through an external wall Fantastically realistic, live flame, open coal fire effect Variable convected & radiant heat output from 1.5kW up to 4kW



Yes, that's right, even rooms with no existing, natural draft, chimney or gas flue can now enjoy all the charm and visual appeal of an open, coal effect, gas fire. These clever Powaflue fires have their own fan assisted flue, which is fitted straight through any suitable external wall.

Technical Specification
A= Minimum Opening Width 380
B= Overall Height 590
C= Min Opening Height 540
D= Total width 480
E= Recessed Depth 125
F= Total Depth 145
G= Maximum Fluespan 600
H= Terminal Height 280
I= Terminal Depth 140
Models with cast iron case have a slightly larger projection onto the hearth.

INSTALLATION: This appliance must only be installed by a qualified CORGI installer in accordance with the installation instructions. The fire must only be installed against a suitable external wall having a thickness between 75mm and 725 mm. The required terminal duct length will depend on installation method adopted. The extraction terminal will be located immediately behind the fire, on the outside wall. The terminal location must be such that the expelled combustion products cannot be blown back into the property or any adjacent property. The fire must be fitted onto or into a non-combustible surface (i.e. a brick cavity wall).
FIREPLACE REQUIREMENTS: Clearance above appliance to a combustible shelf which has a projection not more than 150mm (6"), must be at least 835mm (33") above the hearths top surface. For a deeper combustible shelf you will need to increase this clearance (see instructions).
.
Ventilation:
Purpose provided ventilation (air brick) is not normally required. However, the installer must take account of any other appliance fitted in the same room or space and the result of the spillage test. For republic of Ireland ventilation should be provided in accordance with IS813, ICP3, and IS327.
Fireplace requirements: A non-combustible fireplace having a minimum opening 385mm wide, 545mm high. The traditional 16"X22" opening is suitable. A 20mm deep spacer frame is available for use in shallow fire openings or to enable installation into low temperature fire surround packages. The required minimum depth of the fire opening may vary. This is due to the safety zone behind the fire having to be larger for flues that have previously used for solid fuel fires. Minimum depth for a new flue is 145mm. A 20mm spacer frame is available for shallower fireplace openings. A non-combustible hearth must extend a minimum of 100mm (4") in front of the live part of the fire bed and have a minimum width of 680mm (26.8"). The hearths top surface should be 50mm (2") above the level of the surrounding floor or have a fixed fender of the same height around its perimeter.
WARNING: As with any fire, a fixed fire guard should be used when the fire is used in the presence of pets, children, the elderly or the infirm. The energy input and output figures for these appliances have been assessed in accordance with the latest European standards. However performance may vary under fluctuations in flue conditions
.

 