MAIN HEATING GAS FIRES TECHNICAL INFORMATION
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
MODEL
|
|
DIMENSIONS (FITTED)
|
FLUE TYPE
|
PERFORMANCE (PER/HOUR)
|
|
SAFETY
|
|
| |
|
HEIGHT
|
WIDTH
|
DEPTH
|
|
|
INPUT
|
|
HEAT OUTPUT
|
INFORMATION
|
|
|
LEGEND
SUPER
|
682mm
|
670mm
|
302mm
|
Suitable
for unlined
|
2.07kw
|
|
1.38kw
|
|
Hearth
mounting
|
| |
|
|
|
|
225mm
x 225mm
|
min
|
|
min
|
|
only.
|
|
| |
|
|
|
|
brick
built chimneys,
|
|
|
|
|
Minimum
Flue Height
|
| |
|
|
|
|
125mm
diameter
|
5.14kw
|
|
3.60kw
|
|
3m
(118 1/8")
|
| |
|
|
|
|
BS715
flue liner and
|
max
|
|
max
|
|
Atmospheric
Sensing
|
| |
|
|
|
|
flue
systems, Pre-
|
|
|
|
|
Device
|
|
| |
|
|
|
|
cast
flues to BS1289
|
|
|
|
|
|
|
| |
|
|
|
|
1975&1989
|
|
|
|
|
|
|
|
|
MAINFLAME
SUPER
|
685mm
|
674mm
|
273mm
|
Suitable
for unlined
|
2.07kw
|
|
1.38kw
|
|
Hearth
mounting
|
| |
|
|
|
|
225mm
x 225mm
|
min
|
|
min
|
|
only.
|
|
| |
|
|
|
|
brick
built chimneys,
|
|
|
|
|
Minimum
Flue Height
|
| |
|
|
|
|
125mm
diameter
|
5.14kw
|
|
3.60kw
|
|
3m
(118 1/8")
|
| |
|
|
|
|
BS715
flue liner and
|
max
|
|
max
|
|
Atmospheric
Sensing
|
| |
|
|
|
|
flue
systems, Pre-
|
|
|
|
|
Device
|
|
| |
|
|
|
|
cast
flues to BS1289
|
|
|
|
|
|
|
| |
|
|
|
|
1975&1989
|
|
|
|
|
|
|
|
|
ALLURE
|
|
666mm
|
708mm
|
179mm
|
Suitable
for unlined
|
1.67mm
|
|
0.95kw
|
|
Hearth
mounting
|
| |
|
|
|
|
225mm
x 225mm
|
min
|
|
min
|
|
only.
|
|
| |
|
|
|
|
brick
built chimneys,
|
|
|
|
|
Minimum
Flue Height
|
| |
|
|
|
|
125mm
diameter
|
5.13kw
|
|
3.14kw
|
|
3m
(118 1/8")
|
| |
|
|
|
|
BS715
flue liner and
|
max
|
|
max
|
|
Atmospheric
Sensing
|
| |
|
|
|
|
flue
systems, Pre-
|
|
|
|
|
Device
|
|
| |
|
|
|
|
cast
flues to BS1289
|
|
|
|
|
Unique
shaped top
|
| |
|
|
|
|
1975&1989
|
|
|
|
|
mounted
control,
|
| |
|
|
|
|
|
|
|
|
|
|
(designed
with the
|
| |
|
|
|
|
|
|
|
|
|
|
help
of representatives
|
| |
|
|
|
|
|
|
|
|
|
|
from
Arthritis care
|
| |
|
|
|
|
|
|
|
|
|
|
and
The Royal
|
| |
|
|
|
|
|
|
|
|
|
|
Society
for The Blind.
|
|
|
BRAVA
|
|
666mm
|
713mm
|
173mm
|
Suitable
for unlined
|
1.67mm
|
|
0.95kw
|
|
Hearth
mounting
|
| |
|
|
|
|
225mm
x 225mm
|
min
|
|
min
|
|
only.
|
|
| |
|
|
|
|
brick
built chimneys,
|
|
|
|
|
Minimum
Flue Height
|
| |
|
|
|
|
125mm
diameter
|
5.13kw
|
|
3.14kw
|
|
3m
(118 1/8")
|
| |
|
|
|
|
BS715
flue liner and
|
max
|
|
max
|
|
Atmospheric
Sensing
|
| |
|
|
|
|
flue
systems, Pre-
|
|
|
|
|
Device
|
|
| |
|
|
|
|
cast
flues to BS1289
|
|
|
|
|
Unique
shaped top
|
| |
|
|
|
|
1975&1989
|
|
|
|
|
mounted
control,
|
| |
|
|
|
|
|
|
|
|
|
|
(designed
with the
|
| |
|
|
|
|
|
|
|
|
|
|
help
of representatives
|
| |
|
|
|
|
|
|
|
|
|
|
from
Arthritis care
|
| |
|
|
|
|
|
|
|
|
|
|
and
The Royal
|
| |
|
|
|
|
|
|
|
|
|
|
Society
for The Blind.
|
|
|
CHARM
|
|
666mm
|
713mm
|
173mm
|
Suitable
for unlined
|
1.67mm
|
|
0.95kw
|
|
Hearth
mounting
|
| |
|
|
|
|
225mm
x 225mm
|
min
|
|
min
|
|
only.
|
|
| |
|
|
|
|
brick
built chimneys,
|
|
|
|
|
Minimum
Flue Height
|
| |
|
|
|
|
125mm
diameter
|
5.13kw
|
|
3.14kw
|
|
3m
(118 1/8")
|
| |
|
|
|
|
BS715
flue liner and
|
max
|
|
max
|
|
Atmospheric
Sensing
|
| |
|
|
|
|
flue
systems, Pre-
|
|
|
|
|
Device
|
|
| |
|
|
|
|
cast
flues to BS1289
|
|
|
|
|
Unique
shaped top
|
| |
|
|
|
|
1975&1989
|
|
|
|
|
mounted
control,
|
| |
|
|
|
|
|
|
|
|
|
|
(designed
with the
|
| |
|
|
|
|
|
|
|
|
|
|
help
of representatives
|
| |
|
|
|
|
|
|
|
|
|
|
from
Arthritis care
|
| |
|
|
|
|
|
|
|
|
|
|
and
The Royal
|
| |
|
|
|
|
|
|
|
|
|
|
Society
for The Blind.
|
|
|
DÉCOR
|
|
666mm
|
708mm
|
173mm
|
Suitable
for unlined
|
1.67mm
|
|
0.95kw
|
|
Hearth
mounting
|
| |
|
|
|
|
225mm
x 225mm
|
min
|
|
min
|
|
only.
|
|
| |
|
|
|
|
brick
built chimneys,
|
|
|
|
|
Minimum
Flue Height
|
| |
|
|
|
|
125mm
diameter
|
5.13kw
|
|
3.14kw
|
|
3m
(118 1/8")
|
| |
|
|
|
|
BS715
flue liner and
|
max
|
|
max
|
|
Atmospheric
Sensing
|
| |
|
|
|
|
flue
systems, Pre-
|
|
|
|
|
Device
|
|
| |
|
|
|
|
cast
flues to BS1289
|
|
|
|
|
Unique
shaped top
|
| |
|
|
|
|
1975&1989
|
|
|
|
|
mounted
control,
|
| |
|
|
|
|
|
|
|
|
|
|
(designed
with the
|
| |
|
|
|
|
|
|
|
|
|
|
help
of representatives
|
| |
|
|
|
|
|
|
|
|
|
|
from
Arthritis care
|
| |
|
|
|
|
|
|
|
|
|
|
and
The Royal
|
| |
|
|
|
|
|
|
|
|
|
|
Society
for The Blind.
|
|
|
ESQUIRE
|
|
666mm
|
708mm
|
173mm
|
Suitable
for unlined
|
1.67mm
|
|
0.95kw
|
|
Hearth
mounting
|
| |
|
|
|
|
225mm
x 225mm
|
min
|
|
min
|
|
only.
|
|
| |
|
|
|
|
brick
built chimneys,
|
|
|
|
|
Minimum
Flue Height
|
| |
|
|
|
|
125mm
diameter
|
5.13kw
|
|
3.14kw
|
|
3m
(118 1/8")
|
| |
|
|
|
|
BS715
flue liner and
|
max
|
|
max
|
|
Atmospheric
Sensing
|
| |
|
|
|
|
flue
systems, Pre-
|
|
|
|
|
Device
|
|
| |
|
|
|
|
cast
flues to BS1289
|
|
|
|
|
Unique
shaped top
|
| |
|
|
|
|
1975&1989
|
|
|
|
|
mounted
control,
|
| |
|
|
|
|
|
|
|
|
|
|
(designed
with the
|
| |
|
|
|
|
|
|
|
|
|
|
help
of representatives
|
| |
|
|
|
|
|
|
|
|
|
|
from
Arthritis care
|
| |
|
|
|
|
|
|
|
|
|
|
and
The Royal
|
| |
|
|
|
|
|
|
|
|
|
|
Society
for The Blind.
|
|
|
KNIGHTSBRIDGE
|
675mm
|
552mm
|
250mm
|
Suitable
for unlined
|
4.20kw
|
|
1.90kw
|
|
Hearth
mounting
|
|
ASD
|
|
|
|
|
225mm
x 225mm
|
min
|
|
min
|
|
only.
|
|
|
(Inset
living flame
|
|
|
|
brick
built chimneys,
|
|
|
|
|
Minimum
Flue Height
|
|
effect
gas fire)
|
|
|
|
125mm
diameter
|
5.70kw
|
|
2.85kw
|
|
3m
(118 1/8")
|
| |
|
|
|
|
BS715
flue liner and
|
max
|
|
max
|
|
Atmospheric
Sensing
|
| |
|
|
|
|
flue
systems, Pre-
|
|
|
|
|
Device
|
|
| |
|
|
|
|
cast
flues to BS1289
|
|
|
|
|
Unique
shaped top
|
| |
|
|
|
|
1975&1989
|
|
|
|
|
mounted
control,
|
| |
|
|
|
|
|
|
|
|
|
|
(designed
with the
|
|
|